MiniCub ZT-ESS-96kWh

96kWh

Hybrid external

Inquiry

KEY FEATURES

  • Versatile Multi-Application Design

    DC solar-storage all-in-one solution for commercial applications including hotels, factories, and agricultural facilities.

  • Stable & Efficient

    High-performance intelligent air-cooling with precise temperature control.
    Extended battery cycle life for long-term reliability.
    Energy Management System (EMS), including a cloud platform and local dispatch manager.

  • Seamless Grid Switching

    Supports both grid-tied and off-grid modes with fast 20ms automatic switching.

Product Model and Data-Sheets

PV Input Data
Max. Input Power (kWp)

96

Max. Input Voltage (V)

1000

MPPT Operating Voltage Range/ Nominal Input Voltage (V)

150 - 850

Max. Input Current (A)

40 / 40 / 40 / 40

Number of MPPT Trackers

4

Number of Strings per MPPT

2

Battery Data
Cell Type

LFP Battery 3.2V/ 314Ah

Operating Voltage Range (V)

249.6-345.6

Battery Capacity (kWh)

96

AC Output Data (GRID)
Nominal Output Power (kW)

50

Nominal Output Voltage (Vac)

3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V

Nominal Output Frequency (Hz)

50/ 60

Max. Output Current (A)

76 / 72.2

Power Factor

> 0.99 (0.8 leading - 0.8 lagging)

Total Harmonic Distortion (%)

<3

AC Output Data (EPS)
Nominal Output Power (kW)

50

Nominal Output Voltage (Vac)

3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V

Nominal Output Frequency (Hz)

50 / 60

Max. Output Current (A)

76 / 72.2

On/off Grid switching time (ms)

<20

Efficiency
Max. Efficiency (%)

97.8

EU Efficiency (%)

97.4

Protection
Anti-islanding Protection

Yes

Overcurrent Protection

Yes

DC Surge Protection

Type II

AC Surge Protection

Type II

General Data

Max. output power (kW)

45

Dimension [W*D*H] (mm)

800*1665*2260

Weight (kg)

1240

Store Temperature (℃)

0~35 (A year), -20-45 (A month)

Operating Altitude (m)

4000 (Derating above 2000)

Protection Level

IP54

System with ATS

Gen connect to Hybrid

Note: The parameters related to the hybrid inverter are subject to the final selected hybrid inverter.
PV Input Data
Max. Input Power (kWp)

60

Max. Input Voltage (V)

1000

MPPT Operating Voltage Range/ Nominal Input Voltage (V)

150 - 850

Max. Input Current (A)

40 / 40 / 40

Number of MPPT Trackers

3

Number of Strings per MPPT

2

Battery Data
Cell Type

LFP Battery 3.2V/ 314Ah

Operating Voltage Range (V)

249.6-345.6

Battery Capacity (kWh)

96

AC Output Data (GRID)
Nominal Output Power (kW)

30

Nominal Output Voltage (Vac)

3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V

Nominal Output Frequency (Hz)

50/ 60

Max. Output Current (A)

45.6 / 43.3

Power Factor

> 0.99 (0.8 leading - 0.8 lagging)

Total Harmonic Distortion (%)

<3

AC Output Data (EPS)
Nominal Output Power (kW)

30

Nominal Output Voltage (Vac)

3/N/PE, 220 V / 380 V; 3/N/PE, 230 V / 400 V

Nominal Output Frequency (Hz)

50 / 60

Max. Output Current (A)

45.6 / 43.3

On/off Grid switching time (ms)

<20

Efficiency
Max. Efficiency (%)

97.8

EU Efficiency (%)

97.4

Protection
Anti-islanding Protection

Yes

Overcurrent Protection

Yes

DC Surge Protection

Type II

AC Surge Protection

Type II

General Data

Max. output power (kW)

30

Dimension [W*D*H] (mm)

800*1665*2260

Weight (kg)

1240

Store Temperature (℃)

0~35 (A year), -20-45 (A month)

Operating Altitude (m)

4000 (Derating above 2000)

Protection Level

IP54

System with ATS

Gen connect to Hybrid

Note: The parameters related to the hybrid inverter are subject to the final selected hybrid inverter.

download

cases
1MW/2MWh Hybrid Microgrid Project in Chengdu
Location
Chengdu
Application
Zetacube V2
Installed capacity
1MW/2MWh
1MW/3.65MWh ESS in Palestine
Location
Palestine
Application
Zetacube V2
Installed capacity
1MW/3.65MWh
500kW/1044kWh ESS in Ukraine
Location
Ukraine
Application
Zetacube V2
Installed capacity
500kW/1044kWh
125kW/261kWh ESS in France
Location
France
Application
Zetacube V2
Installed capacity
125kW/261kWh
250kW/522kWh ESS in Switzerland
Location
Switzerland
Application
Zetacube V2
Installed capacity
250kW/522kWh
500kW/1044kWh ESS in Ukraine
Location
Ukraine
Application
Zetacube V2
Installed capacity
500kW/1044kWh
500kW/1044kWh ESS in Ukraine
Location
Ukraine
Application
Zetacube V2
Installed capacity
500kW/1044kWh
20kW/128kWh ESS in Vietnam
Location
Vietnam
Application
ZT-16FL
Installed capacity
20kW/128kWh